CRC INDUSTRIES INC -- ELECTRICAL PARTS CLEANER, 02180 -- 6850-00N061406
===================== Product Identification =====================
Product ID:ELECTRICAL PARTS CLEANER, 02180
MSDS Date:09/08/1993
FSC:6850
NIIN:00N061406
=== Responsible Party ===
Company Name:CRC INDUSTRIES INC
Address:885 LOUIS DRIVE
City:WARMINSTER
State:PA
ZIP:18974
Country:US
Info Phone Num:215-674-4300
Emergency Phone Num:215-674-4300
Preparer's Name:JON BROWN
CAGE:CRCIN
=== Contractor Identification ===
Company Name:CRC INDUSTRIES INC
Address:885 LOUIS DR
City:WARMINSTER
State:PA
ZIP:18974
Country:US
Phone:215-674-4300
CAGE:CRCIN
Company Name:CRC INDUSTRIES, INC.
Address:885 LOUIS DRIVE
Box:City:WARMINSTER
State:PA
ZIP:18974-2820
Country:US
Phone:215-674-4300/800-424-9300
CAGE:10136
============= Composition/Information on Ingredients =============
Ingred Name:ETHYLENE, TETRACHLORO-; (TETRACHLOROETHYLENE) (SARA 313)
(CERCLA)
CAS:127-18-4
RTECS #:KX3850000
Fraction by Wt: 85-92%
OSHA PEL:100 PPM, Z-2
ACGIH TLV:25PPM/100STEL,A3
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
Ingred Name:METHANE, DICHLORO-; (DICHLOROMETHANE) (SARA 313) (CERCLA)
CAS:75-09-2
RTECS #:PA8050000
Fraction by Wt: 5-10%
OSHA PEL:500 PPM
ACGIH TLV:50 PPM, A2
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
Fraction by Wt: 1-4%
OSHA PEL:5000 PPM
ACGIH TLV:5000PPM/30000STEL
Ingred Name:OTHER PREC: DO NOT USE IN THE GENERAL VICINITY OF ARC
WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR UV (ING 5)
RTECS #:9999999ZZ
Ingred Name:ING 4: RADIATION MAY CAUSE THE FORMATION OF HCL AND/OR
PHOSGENE .
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES/SKIN: IRRITATION.
INHALATION: CAUSES CENTRAL NERVOUS SYSTEM EFFECTS, DIZZINESS,
DRUNKENNESS, HEADACHES, IRRITATION TO UPPER RESPIRATORY TRACT,
UNCONSCIOUSNESS AND IRREGULAR HEARTBEATS. CHR ONIC: REPEATED
OVEREXPOSURES HAVE CAUSED LIVER AND KIDNEY EFFECTS IN LABORATORY
ANIMALS. (EFTS OF OVEREXPOSURE)
Explanation of Carcinogenicity:METHYLENE CHLORIDE: IARC MONO, SUPP, VOL
7, PG 194, 1987: GROUP 2B. NTP 7TH ANNUAL REPORT ON CARCINS, 1994:
(SUP DAT)
Effects of Overexposure:HLTH HAZ: CHLOROCARBON MATERIALS HAVE PRODUCED
SENSITIZATION OF THE MYOCARDIUM TO EPINEPHRINE IN LABORATORY
ANIMALS AND COULD HAVE A SIMILAR EFFECT IN HUMANS. ADRENOMIMETICS
(E.G., EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR
LIFE-SUSTAINING USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED TO
CHLOROCARBONS .
Medical Cond Aggravated by Exposure:RISK TO YOUR HEALTH DEPENDS ON
LEVEL AND DURATION OF EXPOSURE.
======================= First Aid Measures =======================
First Aid:INHALATION: REMOVE TO FRESH AIR. APPLY ARTIFICIAL RESPIRATION
IF NECESSARY. EYES: FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST
15 MINUTES. SKIN: REMOVE CONTAMINATED CLOTHING. WASH EXPOSED AREA
WITH SOAP AND WATER. INGESTION: DO NOT INDUCE VOMITING. CALL MD.
===================== Fire Fighting Measures =====================
Flash Point:NONE.
Extinguishing Media:USE WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
& FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:AEROSOL CONTAINERS MAY EXPLODE IF HEATED
ABOVE 120F. THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE HCL AND
PHOSGENE .
================== Accidental Release Measures ==================
Spill Release Procedures:KEEP OUT OF WATER SUPPLY. VENTILATE AREA. DO
NOT ENTER SPILL AREA WITHOUT RESPIRATOR. DIKE AREA AND PUMP INTO
CONTAINERS OR USE ABSORBENT TO PICK UP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A COOL, DRY AREA.
Other Precautions:SINCE VAPS HVR/AIR, PROD SHOULD NOT BE USED IN
CONFINED AREAS/LOW SPOTS W/OUT ADEQ VENT. IF VAPS SUSPECTED IN LOW
AREA, DO NOT ENTER UNLESS SPECIAL BRTHG APPARATUS IS USED &
OBSERVER IS PRESENT FOR AS SIST. NO SMKNG IN AREA OF USE. (ING 4)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:ABOVE TLV USE NIOSH/MSHA APPROVED POSITIVE
PRESSURE SCBA.
Ventilation:MAINTAIN VAPOR CONCENTRATIONS BELOW TLV. USE MECHANICAL
VENTILATION IF NECESSARY.
Protective Gloves:SOLVENT-RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:NOT NORMALLY REQUIRED WITH AEROSOL USAGE.
EMERGENCY EYEWASH & DELUGE SHOWER MEETING ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FL PT METH: TCC, TOC, COC. CARCIN EXPLAN: ANTICIPATED TO BE CARCIN
ANIMAL: LUNG, LIVER, SALIVARY, MAMMARY GLAND (TUMORS).
TETRACHLOROETHYLENE: IARC MONO, SUPP, VOL 7, PG 355, 1987: GROUP
2B. NTP 7TH A NNUAL REPORT ON CARCINS, 1994: ANTICIPATED TO BE
CARCIN ANIMAL: LIVER TUMORS.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:<250F,<121C
Spec Gravity:1.60 @ 70F
Evaporation Rate & Reference:RAPID
Solubility in Water:SLIGHT
Appearance and Odor:COLORLESS LIQUID, WITH IRRITATING ODOR AT HIGH
CONCENTRATIONS
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
AVOID STORAGE IN ALUMINUM CONTAINERS OR CONTACT WITH ALUMINUM AND/OR
ZINC POWDERS.
Stability Condition to Avoid:AVOID OPEN FLAMES, ARCS OR HIGH
TEMPERATURES.
Hazardous Decomposition Products:THERMAL: HYDROGEN CHLORIDE, CHLORINE,
AND SOME PHOSGENE.
==================== Disposal Considerations ====================
Waste Disposal Methods:ALL USED AND UNUSED PRODUCT SHOULD BE DISPOSED
OF IN CONFORMANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.